Help

Heise Model PTE-1 Dual Display LCD Handheld Digital Calibrator Available

The Heise PTE-1 has set a new standard for precision pressure test and measurement instrumentation. With the unique Quick Select® modular sensor system, the PTE-1 can be easily configured to measure ranges from 0-.25” H2O to 0-10,000 psi.

Quick Select® interface modules add temperature measurement with RTDs or thermocouples, while on-board jacks provide measurement of voltage and current (mA). Two sensor bays and a twin LCD provide simultaneous display of any two measurements.

Application specific features support common calibration tasks such as setting pressure switches and relief valves and calibrating pressure transducers. With the datalogging option, calibration results can be stored for subsequent upload to a PC.
Field tested and proven reliable, the Heise® PTE-1 is the popular choice for portable pressure calibration around the world.

For benchtop applications, the model ST-2H is similarly equipped and shares the same Quick Select® modules.

Standard Features
· Measures pressure and temperature (with RTD & thermocouple interface modules)
· Measures mA and volts via on-board input jacks
· Can hold 2 sensor modules and display any 2 readings simultaneously
· Measures high static D/P across two modules
· Ranges from 0-0.25" H20 to 0-10,000 psi
· Also available in compound, absolute, vacuum and differential ranges
· Accuracies from 0.1 to 0.025% FS
· Push-button zero adjust
· Trip point/deadband calculation for pressure switch calibration
· "% accuracy" feature for transducer/transmitter calibration
· Min/Max memory for relief valve setting and burst testing
· 1 programmable and 12 selectable engineering units
· Pressure decay rate calculation for leak testing
· Variable damping
· Tare eliminates pre-existing system pressure
· RS232 output
· Field calibration capability
· Gas flow calculation with pitot tube or annubar
· Runs on 2 alkaline 9v batteries (or optional AC power adapter)
· NIST traceable certificate of calibration


Optional Features
· Intrinsic safety / FM approved, Class 1, Division 1
· EMI/RFI immunity per CE requirements
· Data logging & upload of up to 714 data points
· Enhanced LCD for low temperature operation
· Enhanced sensor processing; maintains rated accuracy from 20-120° F
· AC power adapter

For more information visit www.heise.com

ARCHIVED NEWS

2008
2007
2006
2005
2004
2003
2002
2001
2000

 


eCalibration.com
PO Box 830 ~ State College, PA 16804
P: 800-982-2388 ~ P: 814-234-2417 ~ F: 814-234-7077
editor@ecalibration.com
News ~ Events ~ Directories ~ Careers ~ Resources ~ Global ~ Life Sciences ~ Home
Terms of Use ~ Privacy Statement
© Blue Mountain Quality Resources
eCalibration and The Premier Calibration Resource are Trademarks of Blue Mountain Quality Resources